GPU comparison

Vera Rubin vs B300

Rubin vs Blackwell Ultra on NVIDIA's figures: 288 vs 270 GB, 19.2 vs 7.7 TB/s, dense FP4, power, cooling and CUDA, and whether to build on B300 now.

Faiz Ahmed10 min read
NVIDIA · Rubin

Vera Rubin

Dedicated hardware, built to order

288 GBHBM4 memory
Bandwidth
19.2 TB/s
FP8 compute
Native FP8
How you get itBuilt to order
Plan capacity
NVIDIA · Blackwell Ultra

B300

Dedicated hardware, built to order

270 GBHBM3E memory
Bandwidth
7.7 TB/s
FP8 compute
Native FP8
How you get itBuilt to order
Plan capacity

Rubin has about 2.5 times the dense FP4 and the memory bandwidth of a B300, and almost the same memory: 288 GB of HBM4 against 270 GB of HBM3E per GPU. It also needs liquid cooling in NVIDIA's eight-GPU system, about 24 kW against about 14 kW, and a CUDA release that reached general availability in November 2026. NVIDIA marks HGX B300 servers as shipping now, and for Rubin it lists the Vera Rubin NVL72 rack as available. The decision is therefore less about the chip than about your room, your software and your date. QuantaCloud builds both to order as reserved capacity, and neither is sold by the hour.

Rubin vs B300 specs#

Memory is the one row that barely moves. These are NVIDIA's figures: the Vera Rubin datasheet (October 2026), the Blackwell Ultra datasheet (October 2025) and the HGX, Vera Rubin NVL72 and DGX pages as read on 2026-11-12. NVIDIA publishes Blackwell's FP8, BF16 and INT8 figures with sparsity and Rubin's dense, so the table halves the Blackwell ones to compare dense with dense.

Per GPUB300RubinWhat changes
ArchitectureBlackwell Ultra, compute capability 10.3 (sm_103)Rubin, compute capability 10.7 (sm_107)New compile target, same major version
GPU memory270 GB HBM3E288 GB HBM41.07x on paper
Memory bandwidth7.7 TB/s19.2 TB/s2.5x
FP4 Tensor Core, dense14 PFLOPS35 PFLOPS2.5x
FP4 Tensor Core, sparse18 PFLOPS50 PFLOPS2.8x
FP8/FP6, dense4.5 PFLOPS17.5 PFLOPS3.9x
FP16/BF16, dense2.25 PFLOPS4 PFLOPS1.8x
FP3275 TFLOPS130 TFLOPS1.7x
FP641.2 TFLOPS33 TFLOPSRestored
INT8, denseAbout 154 TOPS (307 sparse)250 TOPS1.6x
NVLink5th generation, 1.8 TB/s6th generation, 3 TB/s1.7x
Host linkPCIe Gen6, 256 GB/sPCIe Gen6, 256 GB/sSame
Max powerUp to 1,100 WNo limit publishedNVIDIA's NVL4 projections assume 1,800 W

The Rubin column uses the per-GPU figures on NVIDIA's Vera Rubin NVL72 page. An eight-GPU server is the fairer match for a B300, and there the memory gap disappears:

Eight-GPU serverHGX B300HGX Rubin NVL8What changes
GPU memory2.1 TB2 TBAbout the same
Memory bandwidth62 TB/s130 TB/s2.1x
FP4, dense108 PFLOPS270 PFLOPS2.5x
FP8/FP6, dense36 PFLOPS130 PFLOPS3.6x
FP6410 TFLOPS265 TFLOPSRestored
NVLink through the switch14.4 TB/s24 TB/s1.7x
Network port per GPU (DGX)800 Gb/s ConnectX-8800 Gb/s ConnectX-9Same speed
Host CPU (DGX)2 Intel Xeon 6776P2 Intel Xeon 6776PSame, with a Vera CPU as the other HGX option
System power (DGX)About 14 kWAbout 24 kW1.7x
Cooling and size (DGX)Air-cooled, 10 RULiquid-cooled, 2 RUA coolant loop instead of airflow

Memory: 288 GB against 270 GB#

Memory does not decide this comparison. On NVIDIA's tables a Rubin GPU has 18 GB more than a B300, and NVIDIA lists 2 TB for the eight GPUs of an HGX Rubin NVL8 against 2.1 TB for an HGX B300. The per-GPU figures may not even be counted the same way: NVIDIA's MIG guide calls the B300 a 288 GB product too, with a largest profile of 269 GB. A model that needs a second B300 server needs a second Rubin server too. The B300 page has the fit table: at vLLM's default setting the engine gets 247.1 GiB of a B300 (our calculation from the 275,040 MiB it reports). I have not found a measured figure for a Rubin GPU, so I do not quote a budget for one.

What Rubin changes is how fast that memory is read: 19.2 TB/s per GPU against 7.7. NVIDIA's own engineers describe the decode phase of inference, where tokens are generated one at a time, as bound by the memory subsystem. That makes bandwidth, more than capacity, the reason to pick Rubin for serving.

Compute: 2.5 times the dense FP4#

Rubin's figures are higher in every floating-point format, and FP8 gains more than FP4. Dense FP4 goes from 14 to 35 PFLOPS per GPU and dense FP8 from 4.5 to 17.5. NVIDIA's headline 50 PFLOPS is a sparse figure that depends on the adaptive compression in Rubin's Transformer Engine, and the like-for-like B300 figure is 18. Rubin also restores what Blackwell Ultra gave up: 33 TFLOPS of FP64 per GPU against 1.2.

NVIDIA's own performance claims are against the older B200. It projects 10 times the token throughput of an HGX B200 for an HGX Rubin NVL8, and the same pretraining with a quarter of the GPUs. Both carry the note that projected performance is subject to change, the inference one compares sparse FP4 on Rubin with dense FP4 on the B200, and the pages I read give no projection against the B300. These are specifications, not measurements, and I have no benchmark of the two on one workload to show you.

Power, cooling and the room#

The room is where the two differ most. NVIDIA's DGX B300 is air-cooled, fills 10 rack units and draws about 14 kW. Its DGX Rubin NVL8 is liquid-cooled, fills 2 rack units and draws about 24 kW, and NVIDIA's HGX specification gives a 45°C inlet temperature. A Rubin server needs a coolant loop where a B300 server needs airflow, and in NVIDIA's own systems it puts 1.7 times the power into a fifth of the space.

Per kilowatt, the gain is smaller than per GPU. The DGX Rubin NVL8 delivers 11.25 dense FP4 PFLOPS per kW against 7.71 for the DGX B300, about 1.5 times (our calculation: 270 / 24 and 108 / 14). At rack scale the ratio is similar: a Vera Rubin NVL72 delivers 2,520 dense FP4 PFLOPS for 227 kW at NVIDIA's highest power setting, against 1,080 for up to 142 kW on a GB300 NVL72, about 1.5 times per kW (our calculation: 11.1 against 7.6).

The platform around the GPU changes less than the names suggest. An HGX B300 is an x86 server. An HGX Rubin NVL8 can be x86 as well, and NVIDIA's DGX Rubin NVL8 keeps the two Xeon 6776P processors of the DGX B300. The other option is NVIDIA's Vera CPU, an Arm processor with 88 cores, which means arm64 builds of everything you run. NVLink moves from the fifth generation at 1.8 TB/s per GPU to the sixth at 3 TB/s. Between servers the speed stays where it was: one 800 Gb/s port per GPU on both DGX systems. The InfiniBand vs NVLink guide explains which traffic uses which link, and the Vera Rubin page covers the Vera CPU and the rack products.

Software: sm_103 against sm_107#

The B300 runs on a stack that has been public since 2025, and Rubin's reached general availability in November 2026. The B300 needs CUDA 12.9 or newer, a release from May 2025, and an R580 driver, first listed in 580.82.07. Rubin is compute capability 10.7. CUDA 13.4 carried it only as a developer preview that NVIDIA said was not intended for production, CUDA 13.5 is the general-availability release, and newly enabled platforms need an R620 driver, whose first data-center release is dated 2026-11-04.

Frameworks follow with a lag. PyTorch 2.14.0 added awareness of sm_107 for extension builds, and vLLM was still publishing its Rubin images as nightly builds in 0.31.0 and pinned a kernel library with initial Rubin support in 0.32.0. The two GPUs share major version 10, and NVIDIA's rule is that a binary runs on the same major version with an equal or higher minor, so plain sm_100 code should carry from a B300 to Rubin. Kernels built for sm_103a do not. The driver and CUDA version guide shows how to confirm what a server is running.

Build on B300 now or wait for Rubin#

The deciding question is what limits you today: the room, the date, the software, or the chip.

Your situationBuildWhy
An air-cooled room with no coolant loopB300NVIDIA's eight-GPU Rubin system is liquid-cooled
Capacity needed on a date you can plan aroundB300NVIDIA marks HGX B300 as shipping now and says nothing yet for HGX Rubin NVL8
A production stack you do not want to rebuildB300CUDA 12.9 and R580, against CUDA 13.5 and R620 from November 2026
The model is too big for the GPU memoryNeither fixes it288 against 270 GB. Add GPUs or servers
Decode speed at long context is the limitRubin2.5 times the memory bandwidth per GPU
Dense FP4 or FP8 compute is the limitRubin2.5 times the dense FP4 and 3.9 times the dense FP8
FP64 simulationRubin33 TFLOPS against 1.2. The B200 has 37 and ships today
72 GPUs in one NVLink domainA rack, not a serverVera Rubin NVL72 or GB300 NVL72

Waiting only makes sense when one of the Rubin rows describes you and none of the first three does. Work done on a B300 is not lost if you move later: NVIDIA's datasheet calls Rubin's Transformer Engine fully compatible with Blackwell, and plain sm_100 kernels should run on both, since they share major compute-capability version 10.

Availability and price#

NVIDIA marks HGX B300 as shipping now and lists the DGX B300 and the Vera Rubin NVL72 as available. Its HGX page has no shipping note for HGX Rubin NVL8 yet. QuantaCloud builds either to order, and lead time comes back in writing with each quote, before you commit.

NVIDIA publishes no list price for either. Reuters reported on 2026-04-30, citing two industry sources, that a B300 server with eight GPUs was priced at about $550,000 in the United States, up from around $500,000 late in 2025. For Rubin the only dated figure I have is for the rack: on 2026-03-24 a Tom's Hardware source put a Vera Rubin NVL72 at $5 million to $7 million, against $6 million to $6.5 million for an inference-optimized GB300 NVL72. I have found no dated price for an HGX Rubin NVL8 server. QuantaCloud quotes both in writing. The DGX B300 guide explains how NVIDIA's own system differs from the HGX servers we build, and the B300 vs B200 comparison covers the choice inside Blackwell.

Rubin vs B300 questions#

Should I wait for Rubin?

Wait only if three things are true: bandwidth or compute limits your job and memory does not, you have liquid cooling, and you can run a software stack that became generally available in November 2026. If any of the three fails, build on B300 now.

Does Rubin have more memory than a B300?

Slightly. A Rubin GPU has 288 GB against 270 GB, and NVIDIA lists 2 TB for an eight-GPU Rubin server against 2.1 TB for an HGX B300.

Can I test Rubin code before the hardware arrives?

Only partly. The on-demand RTX PRO 6000 Blackwell runs FP4 checkpoints, but it is compute capability 12.0, so it cannot test sm_103 or sm_107 kernels. It is useful for model and serving setup. Stopping an on-demand instance deletes its disk, so copy results off first.


The rule I follow: build on B300 when the room is air-cooled, the date matters or the stack has to stay put, and order Rubin when memory bandwidth or dense compute is what holds the job back and the site has liquid cooling. If you are not sure, send one brief on the reserved capacity page with the model, precision, context length, GPU count and site, and ask for both configurations. QuantaCloud will quote each in writing with its lead time.

Plan a Rubin or B300 build

Keep building

Choose your next step.